QuestenaPractice that shows what to review next
Topic lesson

Measure the mechanism, not just the symptom

About 8 min

Questions stay in the language in which they were published.

Extra-class practice questions often present several technically familiar terms and ask which one belongs to the measurement or failure in front of you. Start at the physical boundary: what quantity enters the instrument, what reference sets its accuracy or limit, and where an unwanted signal is first created.

Build a measurement chain

An oscilloscope shows amplitude against time; a frequency-domain instrument shows amplitude against frequency; a vector network analyzer applies a stimulus and measures reflection or transmission at its ports. Once the domain is fixed, locate the controlling reference. A digitizer's sampling rate limits faithfully represented frequency and undersampling folds energy into a false lower-frequency trace. Its reference voltage instead sets amplitude headroom. A frequency counter compares counted cycles with a gate interval, so its time base transfers its fractional error directly to the reading.

Question shapeFirst move
Power flowKeep forward, reflected and absorbed power separate; absorption is the forward flow less the returning flow
Link budgetWrite one signed dB ledger: source power and antenna gains add, cable and path losses subtract
Receiver impairmentName the first mechanism: oscillator sidebands, nonlinear mixing, gain compression or front-end overload
Cable interferenceTrace the return path; currents moving together on the cable can make the entire assembly an antenna

For a margin calculation, first find received level from the signed ledger. Then form the required level from receiver threshold plus the required signal-to-noise ratio. Margin is received level minus required level; preserve both minus signs until the final subtraction. For conducted or radiated interference, classify the path before choosing a remedy. Differential current leaves on one conductor and returns on another; a common-mode component moves in the same direction on the conductors and returns through the surroundings, so shielding material alone does not guarantee containment.

The traps

Try it

Question 184

How much power is being absorbed by the load when a directional power meter connected between a transmitter and a terminating load reads 100 watts forward power and 25 watts reflected power?

  1. 100 watts
  2. 125 watts
  3. 112.5 watts
  4. 75 watts
Question 214

What is the link margin in a system with a transmit power level of 10 W (+40 dBm), a system antenna gain of 10 dBi, a cable loss of 3 dB, a path loss of 136 dB, a receiver minimum discernable signal of -103 dBm, and a required signal-to-noise ratio of 6 dB?

  1. -8dB
  2. -14dB
  3. +8dB
  4. +14dB
Question 215

What is the received signal level with a transmit power of 10 W (+40 dBm), a transmit antenna gain of 6 dBi, a receive antenna gain of 3 dBi, and a path loss of 100 dB?

  1. -51 dBm
  2. -54 dBm
  3. -57 dBm
  4. -60 dBm
Start drillPractice this topic